Before & After

Radon Mitigation in Colorado Springs, CO 80908

For this radon mitigation project in Colorado Springs, CO, Purple Mountain Radon installed a sub-slab depressurization system to address elevated radon levels in the main level of this slab-on-grade home, constructed in 1973. Located in the foothills of the Rocky Mountains, the home faced radon infiltration through the foundation.

 

Given the unique layout, with an HVAC supply duct embedded in the slab, coring through the floor was not feasible. Instead, Purple Mountain Radon used horizontal coring through the foundation wall to reach beneath the slab. This method was ideal to avoid disrupting the interior aesthetics, as the HVAC duct extended around the perimeter and would have interfered with a standard radon pipe installation. By carefully navigating these obstacles, the team successfully reduced the radon risk while preserving the home's design.